Variable Speed Air Cooled Chillers

water cooled portable chiller, small water chiller units, portable water chiller units

The Most Efficient Air Cooled Industrial Process Chiller on the Market

  • Air cooled chiller systems offering 1 to 30 tons cooling capacity
  • Variable Speed (VS) compressor operates effectively between 10% and 100% of rated capacity
  • Energy savings between 30% to 50% of initial investment
  • Standard operating range from -10°F (-23°C) to 100°F (38°C)
  • State of the art, adaptive controls with remote communication options and Industry 4.0 ready
Download Technical Specs

The Delta T Systems “VS Chiller” with the variable speed compressor operates effectively between 10% and 100% of its rated capacity. This means a 10 ton chiller can operate very efficiently as a 1 ton as well as up to a 10 ton chiller. This new design applies proven, variable speed “green” compressor technology from the HVAC industry to produce up to a stunning 50% energy savings over traditional hot gas bypass regulation. These energy cost savings can pay for the chiller investment in less than 3 years. In addition, utility companies may offer purchasing incentives and rebates.

An Air Cooled Chiller System is designed to use ambient air surrounding the condensing unit to cool a refrigerant back into a liquid once it has absorbed heat from the process. Portable, air cooled style chillers refer to a configuration that contains a refrigeration circuit, a reservoir and pump, along with controls.

Whether you need an air cooled process chiller for industrial or other processing applications, Delta T Systems guarantees that our experienced engineers can help you select the right air cooled chiller for your application or customize it to fit and function to your specifications.

Refrigeration Features

  • Hermetically sealed variable speed compressor technology
    • Energy savings between 30% and 50% of the initial investment
    • Soft start
    • Less wear and tear compared to compressor cycling
    • Inverter drive protects compressor from power spikes
    • Tight temperature control within ½ a degree
    • Can overspeed compressor to obtain higher capacities
    • Scroll compressors on the 40 to 60 ton models
  • Stainless steel, copper brazed plate evaporator
    • Non-ferrous – will not rust
    • Less chance of fouling due to its inherent small channels producing high velocities keeping the channels clear.
  • Variable speed condenser fan
    • Operates at the most efficient point
    • Lowers noise since it runs at the minimum speed required
  • Electronic expansion valve
    • Fine tunes the amount of refrigerant needed to maintain the system at the most efficient operating point
    • Allows for a larger operating temperature range without sacrificing temperature control or adding expensive refrigeration controls
  • Microchannel aluminum condenser coils (All air cooled models)
    • Less refrigerant required due to smaller refrigerant tubes
    • Eliminates galvanic corrosion as seen with copper tube and aluminum fin designs
  • Coaxial condensers (2 to 10 ton water cooled models)
  • Cleanable shell and tube condensers (20 to 60 ton water cooled models)

Water Features

  • Non-ferrous chilled water piping
  • Evaporator inlet strainer
    • Easy access and serviceability for cleaning or removal
    • Larger filter area vs. a typical y-strainer equates to less time between cleanings
  • Standard operating range from -10°F (-23°C) to 100°F (38°C)
  • Tight temperature control to within 0.5°F
  • Automatic bypass in low/no flow scenarios to protect unit

Sensor Features

  • Refrigerant suction and discharge pressure transducers
    • Allows the compressor to adjust its speed to adapt to the best efficient and safe condition to reduce down time
    • Actual pressure information is displayed and captured to reduce the time to troubleshoot
    • Eliminates fragile copper capillary tubes
  • Refrigerant suction and liquid line temperatures sensors for superheat and subcool readings
  • Compressor discharge temperature sensor for compressor protection
  • Chilled water in and out pressure and temperature sensors
  • Tank level sensor

Cabinet Features

  • Fits through a standard 36 inch doorway (needs to be 34-1/2 inches or less to meet this due to door stops)
  • Small footprint (34×34 on 5 and 7.5 ton, 34×46 on 10 and 15 ton)
  • Can fit in standard shipping container – tallest chiller (15 ton) is 85 inches
  • Full access on all sides with lift off panels
  • Separate air section so chiller can be serviced by removing panel without creating faults
  • Round coil allows for locating chiller up against a wall

Electrical Features

  • NEMA 12 electrical panel
  • Disconnect switch
  • 24 V controls
  • Finger safe electrical components
  • Phase monitor
  • 4 inch touch screen display
  • State of the art controls
    • Flexible remote communication options
    • Extensive digital data collection
    • Adaptive control to reduce downtime

Control Features

  • Proprietary Control Platform from the leader in the HVAC and refrigeration industry
    • Integrated Ethernet interfaces offer a wide range of open protocols (Web server, Modbus/TCP, BACNet, FTP, DHCP, DNS, NTP) (optional)
    • Cloud services (optional)
  • 4 Inch Touch Screen Display
  • Adaptive Control
    • Uses the systems pressures, temperatures, and compressor drive information to operate the chiller at the most efficient operating point while maintaining the predefined compressor operating envelope limits
    • Changes the speed of the compressor should any of the parameters approach a fault condition in order to reduce customer downtime.
  • Data Logging
    • Logs temperature and pressure data continually for historical reference
    • Captures data at the time of an alarm event
  • Remote Monitoring (optional)

Bonus Features

  • Dewpoint sensing and setpoint tracking
  • 50 Hz applications without a cooling capacity derate
  • Modbus RTU or BACnet MS/TP RS485 communication
  • Remote start/stop
  • Cooling enabled output
  • Automatic water bypass
  • Flow indication
  • Dirty strainer indication
  • Tank level indication
  • Low and high level indication

Options

  • Remote display
  • Overhead piping kit
  • Mounting feet in lieu of casters
  • No pump, no tank
  • Pump, no tank
  • Ship loose pump, no tank
  • Auto water make-up
  • 50 micron side stream filter (factory installed)
  • 50 micron full flow filter (factory installed)
  • Alarm horn
  • Alarm strobe
  • Remote alarm contacts
  • Remote access to control
  • UL 508a
  • SNMP, Modbus TCP/IP, BACnet Ethernet Communication
  • Outdoor / outdoor coastal
  • Dust air filters
  • Anti-drain back design
  • Supply and return valves
  • Pump VFDs
  • Medium and high pressure fans for ducted applications
ModelMaximum Capacity1
(BTUH)
Minimum Load
(BTUH)
Condenser Air Flow
(CFM)
Reservoir
(Gallons)
Minimum Circuit
Ampacity2
Dimensions (in)
Height3, Width, Depth
Shipping Weight
(with crate) (lbs)
VSPA-00115,5701,217667125.5522030440
VSPA-00228,4062,4021,341129.3522034470
VSPA-00348,6723,6031,9371211.4522034495
VSPA-00565,6536,0013,3172518.0643434705
VSPA-00888,9699,0054,5412519.5753434760
VSPA-010138,20512,0046,5694027.5753446865
VSPA-015182,71218,0039,7264039.3853446875
VSPA-020276,67424,00813,1387048.57534951,640
VSPA-025326,12530,02019,4527060.67534921,755
VSPA-030365,42536,00619,4527069.48634951,835
(1) Capacity based on 50°F LWT, 95°F ambient, maximum speed
(2) MCA based on standard pump option. Will change with different pumps.
(3) Add approximately 6” for optional alarm horn and strobe.
One Circuitair Cooled Chiller Drawing Outside ViewVSPA-001 to VSPA-0015
2 Circuit Air Cooled Chiller Drawing Outside ViewVSPA-020 to VSPA-030
Download Technical Specs

A chiller equipped with a fixed speed compressor controls the temperature of the water traditionally with simple on/off of the compressor. This means that when the compressor runs, it runs at the designed load regardless of the process needs. A more advanced option is a hot gas bypass which technically keeps the chiller running but bypasses the hot gas if no cooling load is needed. This avoids the on/off of the compressor but results in a waste of energy since no cooling is required from the process.

The Delta T Systems industrial chiller with the variable speed compressor operates effectively between 10% and 100% of the capacity which means a 10 ton chiller can operate efficiently as a 1 ton as well as up to a 10ton chiller.

The Air Conditioning, Heating, and Refrigeration Institute (AHRI) conducted several studies to identify the true amount of time a chiller runs at full vs. partial load. The outcome is an integrated part load value (IPLV). The national average cost for electricity is $0.14/kw-hr. If you assume a 2 shift operation, 5 days a week for one year, the energy savings for a 10 ton chiller are $4,690 or 58% less than a chiller with a fixed speed compressor. These energy cost savings can pay for a chiller in less than 3 years.

These conservatively calculated energy savings can be much higher because most chillers are selected based on the peak usage time of the year which means the chiller is oversized for the average usage.

variable speed air cooled chiller, air cooled chiller system

variable speed air cooled chiller, air cooled chiller system