The Accent Series water temperature control system is our most popular TCU model. It is a single zone, energy efficient water circulating temperature control system suitable for operation up to 250°F (121°C) making it suitable for a wide range of applications.

water circulating temperature control systems, accent series water temperature control unit
  • ¾ to 7 ½ HP Pump, 25 to 100 GPM
  • 9 to 24 KW Low Watt Density Heater
  • 250°F (121°C) Fluid Operating Temperature
  • ¼" Solenoid Valve for Cooling
  • 16" W x 30" D x 26" H

This Water Temperature Control System meets NEMA 1 electrical specifications and conforms to NEC electrical code.

It is equipped with a microprocessor-based PID controller, a horizontally-mounted pump for extended seal life, and a rugged, heavy gauge sheet metal cabinet supported by 3” industrial-grade casters.

Standard Features

  • 9 KW Heater
  • 250°F (121°C) Fluid Operating Temperature
  • Microprocessor-Based PID Controller
  • Horizontally-Mounted Pump to Promote Extended Seal Life
  • Motor Overload Protection
  • Over Temperature Protection
  • Low Water Pressure Protection
  • High Pressure Safety Relief Valve Protection
  • Liquid-Filled Delivery and Return Pressure Gauges
  • Fully-Insulated Heater Tank
  • Fused Transformer
  • Grounded Circuit Control
  • Pilot Lights indicating Separate Functions of Use
  • Rugged, Heavy Gauge Sheet Metal Cabinet
  • 3" Industrial-Grade Casters
  • Ease of Service Design
  • NEMA 1 Electrical Specifications & Wiring in Conformance with NEC Electrical Codes
  • Industrial Grade Casters
  • Automatic Venting

Optional Features

  • Operating Temperature up to 300°F (149°C)
  • 50 and 60 Hz
  • 208–600V
  • UL 508A Certified Electrical Panel - Enclosed types
  • NFPA 79 electrical safety standards
  • NEMA Classifications: 3, 4, 4X, 7 and 12 rated enclosures
  • Customer-Preferred Controllers
  • Communications capability with various protocols (i.e. Modbus, Profibus, Ethernet, etc)
  • Audible or Visual Alarms
  • Pump Rotation Indication
  • Larger Solenoid Valves
  • Electrical Main Disconnect
  • Mercury or Solid State Heating Contactor
  • Heat Exchangers (Closed-Circuit)
  • Modulating Cooling Valve
  • Multiple Zones in a Cabinet or Open Frame
  • 12, 18 and 24 KW Heaters

Please consult us if other options are desired.